Most electrosurgical generators on the veterinary market are adapted from human surgery units with the manufacturer’s logo swapped and maybe a softer beep tone. The EP-200 was designed from the ground up for animal surgery, and the difference shows in the one thing that actually matters in the OR: how much the surgeon has to think about the machine versus the patient. Traditional electrosurgery units require the surgeon to set cutting mode, coagulation mode, and power level before making the first incision — and then adjust those parameters throughout the procedure as tissue type changes. The EP-200 eliminates that entire mental overhead with tissue self-adaptive technology that samples tissue impedance a hundred times per second and adjusts output power in real time. No manual parameter setting. No pausing mid-procedure to dial in new settings. The generator reads the tissue and responds automatically, which means the surgeon stays focused on the animal, not the equipment panel.
This is especially valuable in veterinary surgery because animal tissue varies dramatically across species and breeds — the dermal thickness of a Bulldog versus a Whippet, the vascular density of a feline versus a canine liver, the adipose composition of an obese patient. A fixed-parameter generator forces the surgeon to compensate for these differences with technique. The EP-200 handles them algorithmically, delivering the minimum thermal damage necessary to achieve the surgical objective regardless of tissue variation.
Intelligent Energy Management System
Tissue Self-adapive Technology
No Need to Set the Parameters Manually
Realize Intelligent Operation with One Button
Intelligent Electrosurgical Generator with Vessel Sealing System is a high-performance medi- cal device, which is specially designed for the modern animal operating room. By integrating a variety of advanced cutting and coagulation technologies, it combines two major functions of high-frequency electrosurgical equipment and vessel sealing system into one, and realizes the intelligent output of electrocision and vessel sealing system by advanced tissue self-adapive technology, eliminating the need to manually set the parameters before the operation and providing the surgeon with a precise, safe, efficient, and convenient surgical experience.
Whether it is routine tissue processing or high-precision minimally invasive surgery, this gener- ator meets the complex needs of different surgical styles and is an indispensable right-hand man for the vet in laparoscopic and developmental surgery.
Intelligent identification of tissue state and power adjustment 100 times per second, real-time dynamic adjustment of electrocutting output power, to ensure that the minimum thermal damage to achieve the optimal cutting effect, without the need for doctors to manually adjust the power, convenient, quick, simple and efficient.
Monopolar Mode
4 Kinds of Electrocision Function
Pure Cut Mode
Quick total excision and fine excision of the focus,with a relative weak coagulation effect.
Blend 1 Mode
Fast-speed excision and coagulation of the focus of minor hemorrhage (70% duty cycle output cutting waveform).
Blend 2 Mode
Medium-speed excision and coagulation of the focus of moderate hemorrhage (50%duty cycle output cutting waveform).
Blend Mode
Low-speed excision and coagulation of the focus of large hemorrhage (30% duty cycle output cutting waveform).
3 Kinds of Electrocoagulation Functior
Soft Coagulation
Heat the tissue at a slower rate and increase the depth of thermal penetration,which is suitable for deep and high stability required tissue coagulation.
Typically use the spherical electrodes for coagulation.
Spot Coagulation
The electrode generates a spark that passes through the air to coagulate the tissue,achieving a small,precise coagulation of the targeted tissue.
Surface Coagulation
The spark of electrode has a wider sputtering range,slower penetration speed and can coagulate a larger area of tissue.
| Model | EP-200 |
| Power Output | 200 W maximum |
| Output Frequency | 470 kHz ±10% |
| Operating Modes | Cut (Pure Cut, Blend 1/2/3), Coag (Pinpoint, Spray, Fulgurate), Bipolar |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Input Power | 800 VA |
| Dimensions (W×D×H) | 36 × 35 × 14 cm |
| Weight | ~6.5 kg |
| Patient Plate Monitoring | Contact Quality Monitoring (CQM) system |
| Display | Digital LED display |
| Safety Class | Class I, Type CF applied part |
| Certification | CE, IEC 60601-1, IEC 60601-2-2 |